If you are designing a new system or replacing an existing compressor chiller, Trane can satisfy virtually any application need. Whether coupled with a Trane or. The main chiller components are the Compressor, Condenser, Evaporator, Expansion Valve, Power Panel, Controls unit and the Water Box. Jump to Vapor Compressor Chiller - They include a compressor, evaporator, condenser and a metering device. Vapor-compression chillers typically utilize.


CHILLER COMPRESSOR PDF DOWNLOAD

Author: Mazie Heidenreich DDS
Country: Bulgaria
Language: English
Genre: Education
Published: 24 January 2014
Pages: 680
PDF File Size: 32.75 Mb
ePub File Size: 6.18 Mb
ISBN: 732-6-43415-298-9
Downloads: 46246
Price: Free
Uploader: Mazie Heidenreich DDS

CHILLER COMPRESSOR PDF DOWNLOAD


Compressed refrigerant gas is sent from the compressor to a condenser unit chiller compressor rejects the heat energy from the refrigerant to cooling water or air outside of the system.

How does a chiller system work? - Automation Technology US - Siemens

The transfer of heat allows the refrigerant gas to condense into a liquid which is then sent to a metering device. The metering device restricts the flow of liquid refrigerant which causes a drop in pressure.

The drop in pressure causes the warm refrigerant liquid to change phase from liquid to gas and in doing so absorbs heat from the water to be cooled due to adiabatic flash evaporation. The metering device is positioned so that the expanding refrigerant gas is contained within the evaporator, transferring the heat energy from the water to be cooled into the refrigerant gas.

The chiller compressor refrigerant gas is then sent back to the compressor to start the cycle over again and the newly chilled chiller compressor in the separate loop can now be used for cooling.

To the top of the page Absorption Chiller An absorption chiller uses a heat source to drive the refrigeration cycle in place of a mechanical compressor.

Absorption chillers utilize two fluids which include a refrigerant, typically water and an absorbent, typically a lithium bromide solution or ammonia. The solution boils, sending refrigerant vapor upward into the condenser and leaving behind concentrated lithium bromide.

The concentrated lithium bromide chiller compressor moves down to the heat exchanger, where it is cooled chiller compressor the weak solution being pumped up to the generator. The refrigerant vapor migrates through mist eliminators to the condenser tube bundle.

The refrigerant vapor condenses on the tubes.

Chiller Compressors | Danfoss India

The heat is removed by the cooling water which moves through the inside of the tubes. As the refrigerant condenses, it collects in a trough at the bottom chiller compressor the condenser.

The refrigerant liquid moves from the condenser in the upper shell down to the evaporator in the lower shell and is sprayed over the evaporator tube bundle. This vacuum is created by hygroscopic action - the strong affinity lithium bromide has for water - in the Absorber directly below.

As the refrigerant vapor migrates to the absorber from the evaporator, the strong lithium bromide solution from the generator is sprayed over the top of the absorber tube bundle. The strong lithium bromide solution actually pulls the chiller compressor vapor into solution, chiller compressor the extreme vacuum in the evaporator.

Chiller Compressors | Danfoss India

The absorption of the refrigerant vapor into the lithium bromide solution also generates heat which is removed by chiller compressor cooling water. Now the dilute lithium bromide solution collects in the bottom of the lower shell, where it flows down to chiller compressor solution pump.

The chilling cycle is now completed and the process begins once again. The internal tank helps maintain cold water temperature and prevents temperature spikes from occurring. Closed-loop industrial chillers recirculate a clean coolant or chiller compressor water with condition additives at a constant temperature and pressure to increase the stability and reproducibility of water-cooled machines and chiller compressor.

The water flows from the chiller to the application's point of use and back.

CHILLER COMPRESSOR PDF DOWNLOAD

In this case the chilled water is not going directly chiller compressor the chiller to the application, but goes to the external water tank which acts as a sort of "temperature buffer.

The liquid is drawn from the tank, pumped through the chiller and back to the tank. In chiller compressor water chillers is the use of water cooling instead of air cooling.

Chiller - Wikipedia

In this chiller compressor the condenser does not cool the hot refrigerant with ambient air, but uses water that is cooled by a cooling tower. Additionally, the absence of fans allows for significantly reduced noise levels. Bus control Automation means less waste and better process control.

Danfoss AC drives handle the most common bus protocols in the industry and integrate seamlessly chiller compressor the overall control system.

Best-in-class Process Instrumentation and Analytics

Reduced wear chiller compressor tear The embedded Pump Chiller compressor Controller distributes running hours evenly across all pumps. This keeps wear and tear on each individual pump to a minimum, enables optimal predictive maintenance scheduling and increases pump chiller compressor.

Overload prevention AC drive speed is reduced to ensure supply at a lower flow rate. Dry pump protection If a well runs dry or a pipe leaks, the AC drive detects that the pump is running below the desired pressure.



Related Articles: